MENU

DEPARTMENTS AND LABORATORIES

 Departments and Laboratories

Energy Storage Testing Laboratory

oranges-line

The Laboratory provides electrical, mechanical, climatic and safety (included handling and transport) test all types of batteries and cells.

The scope of work at the Laboratory:

  • Examination of electrical, mechanical and klimatic parameters as well as parameters concerning safety of transport or use of all types of batteries.
  • Development, assessment and deployment of new testing methods and measuring and control systems.
  • Cooperation with Polish Centre for Accreditation, respect of rules for laboratory accrediation.

To guarantee high quality of its competences and tests Laboratory has deployed quality management system according to PN-EN ISO/IEC 17025. Since 1997 our facility has been acting as an accredited research unit. Moreover, the Laboratory has Accreditation Certificate no AB 124 issued by Polish Centre for Accreditation (PCA).

To download (in Polish only):

The laboratory offers the following services

  • Parameters testing for all types of energy storage, according to national and international regulations as well as Client's testing programmes or other documents.
  • Handover testing of special products

The Laboratory conducts the following tests: 

  • scope of accreditation
  • capacity (discharge)
  • charge acceptance
  • cold cranking aptitude CCA to 2000A
  • charge retention
  • cycle life
  • water use
  • high-rate discharge
  • qualification as emergency power
  • short circuit current and internal resistance
  • max. voltage of discharge current
  • charge acceptance after deep discharge
  • corrosion resistance
  • overcharge
  • short circuits
  • tests in elevated/lowered temperature conditions  
  • thermal stresses
  • temperature cycling
  • tests in elevated/lowered pressure conditions
  • resistance to elevated humidity
  • sine vibrations and random
  • mechanical shocks

The Laboratory performs tests according to :

  • transport standard UN 38.3
  • PN-EN 50342
  • PN-EN 60086-1 PN-EN 60086-2
  • PN-EN 62133
  • PN-EN 60896-11
  • and other norms, directives or manufacturer’s specifications
Temperature bath
Temperature bath

570 mm x 1200 mm

Max. temperature: 75°C

 

Digatron
Digatron

Digatron UBT 50-12-6 
• Imax  = 50 A; Umax = 12V

Digatron UBT 100-12-3 
• Imax  = 100 A; Umax = 12V

Digatron UBT 200-09-2S
• Imax  = 60A; Umax = 9V
• Imax  = 200A; Umax = 9V

 

Digatron UBT 100-18-4
• Imax  = 100A; Umax = 18V

Digatron HEW 1500-6
• Imax  = 1500A; Umax = 12V

Digatron HEW 2000-12 ME 
• Imax  = 2000A; Umax = 15V

Digatron IBTR 800-36S
• Imax  = 800A; Umax = 36V

Digatron IBTR 1500/400 
• Imax discharge = 1500A  /  30V ÷ 10V
• Imax charge = 400A  /  10V ÷ 36V

Digatron SBT 5-15-2 
• Imax  = 5A; U nominal = 15V

Digatron SBT 5-20-2 
• Imax  = 5A; Umax = 20V

Digatron SBT 5-5-3 
• Imax  = 5A; Umax = 5V

Digatron MCT 5-16-32 
• Imax  = 5A; Umax = 16V

Digatron BNT 50-100-3 
• Imax  = 50A; Umax = 100V

Digatron BNT 50-100-3 
• Imax  = 50A; Umax = 100V

Resistance analyser HIOKI 3554
Resistance analyser HIOKI 3554

  • Four ranges of internal resistance measurement: 3,000m/30,00/300,0/3,000 Ω
  • Measurement frequency: 1 kHz ±30 Hz

Vibration system Tira TV 56280/LS-180

Vibration system Tira
TV 56280/LS-180

Force for process sinus max: 8000 N
Force for process random max: 8000 N
Force for stresses: 16 000 N
Frequency range: DC – 3000Hz

Vacuum climate chamber UD 150 C

Temperature range -70/+100°C

Pressure up to 1 mbar

Temperature chamber

Temperature range
- 80°C  ÷  +180°C

Temperature chamber

Temperature range
- 40°C  ÷  +180°C

Climate chamber

- 70°C  ÷  + 180°C 

Humidity up to 98%

Kamil Frączek, M. A.

tel:.+48 61 27 97 882
fax:. +48 61 27 97 897
mobile:. +48 516 068 981
e-mail: kamil.fraczek@claio.poznan.pl